Hot-end PEEK part melted

Some customers reported constant failure of the Hot-end Peek part in the FELIX 3.1(and older) hot-ends. The causes for this are:

  • Thermistor connected to the wrong hot-end in case of dual head.
  • The thermistor is defect, it measures a lower temperature than it is in reality. The peek part melts when the temperature is above 350 degC. The increase in temperature should be around 3 degC per second. Also a good indication with dual head printing, is to turn on both heaters at the same time from a cold state (less than 30degC). By the time one of the two hot-ends reach their setpoint temperature (a good temp would be 180 degC), the difference in temperature should be less than 10degC.
  • The thermistor fell out of the heater body of the hot-end.Only an issue with older firmare (pre v0.92)
  • Mainboard thermistor circuit is defect or not functioning right. Control board replacement can solve this issue.

A recommended fix is to install a full metal hot-end from the TEC 4. 

Note: Repetier firmware from version 0.92 and upwards have a safety feature built in which prevent the ability of overheating. Always make sure to use the latest firmware on your printer. Get it from here: www.felixprinters.com/downloads

This article was helpful
This article was not helpful
This site uses cookies. By continuing to browse this site you are agreeing to our use of cookies. Find out more here.